Maintaining, repairing and upgrading your HVAC assets are critical. However, the proper operation of your system as well as conformance with regulatory norms and standards are equally critical. That is where balancing and certification becomes important.

Testing, adjusting and balancing keeps your HVAC system operating at peak performance. Testing measures temperatures, pressures, rotational speeds, electrical characteristics, velocities, and air and hydronic quantities for an evaluation of flow conditions. Adjusting is the positioning of dampers and valves, and varying fan speeds to achieve optimum system operating conditions within design and installation limitations. Balancing is the methodical proportioning of air and hydronic flows through the system mains, branches, and terminal devices using acceptable procedures to achieve the specified airflow or hydronic flow within testing and design limitations.

Industries such as healthcare, pharmaceuticals, life sciences, laboratories and datacenters are often subject to certification requirements for conditions including filtering, flow paths and rates, biological safety and pressurization.

 

Our NEBB (National Environmental Balancing Bureau) and TABB (Testing, Adjusting and Balancing Bureau) certified professionals conduct thorough, documented programs to ensure your systems are performing to system specifications. According to these agencies:

Testing is the use of specialized and calibrated instruments to measure temperatures, pressures, rotational speeds, electrical characteristics, velocities, and air and hydronic quantities for an evaluation of flow conditions.

Adjusting is the varying of system flows by partially closing balancing devices, such as dampers and valves, and varying fan speeds to achieve optimum system operating conditions within design and installation limitations.

Balancing is the methodical proportioning of air and hydronic flows through the system mains, branches, and terminal devices using acceptable procedures to achieve the specified airflow or hydronic flow within testing and design limitations.

Besides having the experience with control strategies, sequence of operation, control systems, equipment and software, our NEBB/TABB certified professionals:

  • Develop and plan the work
  • Handle report preparation
  • Recommend corrective actions
  • Set overall safety plans
  • Maintain instruments and their calibration program
  • Review, check, sign and stamp the final TAB report

 

Our service specialists can also talk with you about energy efficiency solutions such as combined heat & power systems and distributed energy resources.

 

“For Service and Information please contact us at:”

Clean Room/Lab Certification:
Email: HEPA@htlyons.com  |  Phone:  484-239-0222 or 484-225-7745


Testing, Adjusting and Balancing
Email: TAB@htlyons.com  |  Phone:  484-239-0222

 

Contact us for your balancing and certifications needs.

Industry Experts

Follow us on linkedin to stay up-to-date

#mepservices Linkedin Page